Air Temperatures
Supply / return / mixed / outside air. Live BAS bindings overlay simulated values when wired.
Air-temps binding: Demo
(bound=0 ·
stale=0 ·
demo=6 ·
missing=0)
- Supply Air
-
55.4 °F (sim)
Demo
- Supply Setpoint
-
55.0 °F (sim)
Demo
- Discharge Setpoint
-
55.0 °F (sim)
Demo
- Return Air
-
73.8 °F (sim)
Demo
- Mixed Air
-
63.2 °F (sim)
Demo
- Outside Air
-
82.1 °F (sim)
Demo
Supply Fan SF-1
Supply fan status and VFD feedback. Simulated.
- Status
- Running
- Speed Cmd
- 68 % (sim)
- VFD Speed
- 68 % (sim)
- VFD Amps
- 42 A (sim)
- VFD Fault
- No fault
Chilled-water cooling coil
Cooling coil valve / DX state. Simulated.
- Coil Kind
- chilled_water
- Valve / Stage
- 44 % open (sim)
- Leaving Air
- 55.4 °F (sim)
- Active
- Yes
Hot-water heating coil
Heating coil valve / stage state. Simulated.
- Coil Kind
- hot_water
- Valve / Stage
- 0 % open (sim)
- Leaving Air
- —
- Active
- No
Outside Air / Economizer
OA damper, RA damper, economizer mode. Simulated.
- OA Damper
- 22 % open (sim)
- RA Damper
- 78 % open (sim)
- Min OA
- 20 % (sim)
- Economizer Mode
- Mech-cooling (high enthalpy)
- Economizer Enabled
- No
Filter / Static Pressure
Filter loading and duct static pressure. Simulated.
- Filter
- Pre-filter / final-filter bank
- Filter ΔP
- 0.62 in. wc (sim)
- Filter Alarm Threshold
- 1.10 in. wc (sim)
- Filter Status
- OK
- Duct Static
- 1.42 in. wc (sim)
- Duct Static SP
- 1.50 in. wc (sim)
- Building Pressure
- 0.04 in. wc (sim)
Alarm History
Recent alarm/abnormal events. Open (manual reset required) listed first. Simulated.
-
2026-05-08 10:14
DA-LO · Supply air temp below low limit (auto-reset)
Auto-reset
-
2026-04-30 06:02
FILTER-DP · Filter differential pressure trending high
Auto-reset
Companion Equipment
VAVs / zones served by this AHU. Read-only links.
VAV-101 · Conf 101
VAV-201 · Conf 202
Other AHUs on this floor:
Point / Detail Navigation
Drill into a specific point or related operator surface. Unresolved kinds render as disabled hint chips.
- supply_air_temp → point_detail (not yet routed)
- return_air_temp → point_detail (not yet routed)
- supply_fan_vfd → point_detail (not yet routed)
- trends → trends (not yet routed)
- alarms → alarms (not yet routed)
- floor_plan → floor_plan
Operator Notes
Supply temp tracking setpoint within 0.6°F.
- Air-temp panel pairs supply/return/mixed/outside so the operator can sanity-check coil work and OA mixing in one glance.
- Supply-fan + VFD panel surfaces commanded speed, measured speed, amps, and fault state — three different fault signatures are distinguishable.
- Cooling and heating coil panels expose valve position and leaving-air temp; activeness flags surface as hero chips for at-a-glance state.
- Filter ΔP shows current loading vs alarm threshold, so a filter-change reminder is obvious before it trips an alarm.
- Alarm history surfaces both auto-reset events and OPEN trips that still require manual intervention.